| Construction - Slope-Measurement |
| |
| MSS-505/MSS-515 Slope Sensor |
|
|
| |
|
The MOBA MSS-505/MSS-515 mobile slope sensor is especially conceptualised for slope monitoring on aerial work platforms.
One distinctive feature of this technology:
the sensor operates without a mercury switch and already meets the requirements of the Regulation EC No. 2210/2008 today.
|
|
| |
|
| Special Features : |
|
- 1-axis-sensor
- Operates with two completely independent (and redundant) channels
- Compact, flat design (80 x 70 x 32 mm) for simple attachment to the machine
- Rugged design with approved sealing, for mobile use
- Optimised for immunity to vibration and acceleration
- Quick measurements – optimal automatic levelling
- Isolation complies with DIN/VDE standard 0682-742
- Does not contain mercury, complies with the requirements of the Regulation EC No. 2210/2008
- Zero point adjustment via infrared interface with remote control unit
- Protection class IP67
|
|
| |
|
|
| |
Duo level sensor III / IV |
|
|
| |
|
- Voltage range: 20...30 V DC
- Measuring ranges: ± 5°; ± 10° (± 5%)
- Current consumption: < 100 mA without indicator
- Stability of the zero point: 0,2°
- Enclosure protection: IP67
|
|
| |
|
|
| |
Duo level displays |
|
|
| |
|
- Voltage range: 20 ...30 V DC
- Max. resolution: 0,2° pro LED
- Current consumption: < 150 mA ohne Geber
- Good readability
- Easy to put into operation
- Easy to use
- Reverse battery protection and protection against voltage spikes
- Change-over switch: 1° / 5° (1% / 5%)
- Enclosure protection:
built-on indicator IP65; built-in indicator IP66
|
|
| |
|
|
| |
Digi level sensor |
|
|
| |
|
- Voltage range: 10 ... 30 V DC
- Current consumption: max. 70 mA @ 24 V
- Measuring ranges: ± 10° (± 17%); ± 60° (± 170%)
- Zero point stability: ± 0,1°
- Interface: CAN
- Enclosure protection: IP67
|
|
| |
|
|
| |
Digi level display |
|
|
| |
|
- Voltage range: 10 ... 30 V DC
- Current consumption: < 200 mA with backlight
- Good readability
- Easy to put into operation
- Easy to use
- Reverse battery protection and protection against voltage spikes
- Indicated value of the inclination: degree or percent
- ± 10° (± 17%); ± 60° (± 170%)
- Interface: CAN
- Enclosure protection: IP65
|
|
| |
|
|
| |